TM 5-3895-369-14
NOTE
Mark all parts so zero swash plate angle
will be retained when the parts are
reassembled. Swash plate is held in zero by
springs inside servo housings which are
adjusted by turning the servo housing.
(33)
(34)
(35)
(36)
(37)
(38)
(39)
(40)
(41)
Remove four screws (67) and two locking
retainers (68).
Mark height of two servo housings (57) in
relation to pump (3) and remove servo
housings and four preformed packings (69).
Discard preformed packings.
Remove six screws (70), lockwashers (71),
two trunnions (72), and swash plate (73).
Discard lockwashers.
Note number and remove shims (74)
and preformed packings (75) from
trunnions (72). Discard preformed packings.
Remove two trunnion bearings (76).
Remove nine screws (77) and washers (78)
from control (79).
Unhook control arm (80) and remove
control (79) and gasket (81) from pump (3).
Discard gasket.
Remove and discard three preformed
packings (82) and aperture plug (83).
Remove nut (84) and lockwasher (85),
lever (86), and spacer (87).
5-329