TM 5-3895-369-14
5-54. HYDROSTATIC PUMP REPAIR (CONT).
(3)
Remove sealing ring (6), six springs (7),
and preformed packings (8 and 9) from
aluminum housing (10). Discard
preformed packings.
(4)
If damaged, remove pin (11).
NOTE
Before removing charge pump, matchmark
housing and main pump end cap.
(5)
Remove six screws (12 and 13),
lo&washers (14 and 15), and lifting
bracket (16) from end cap (17) to pump (3).
Discard lo&washers. Two remaining
screws should be opposite each other on
top and bottom.
NOTE
End cap is under slight internal pressure.
Care should be taken when removing last
two screws.
(6)
Remove remaining two screws (12), lo&washers (14), and end cap (17) from pump (3). Discard
lo&washers.
(7)
Remove gasket (18), locating pin (19), and valve plate (20) from pump (3). Discard gasket.
5-324