HYDROSTATIC MOTOR REPAIR - Continued
HYDROSTATIC MOTOR REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1010    1011    1012    1013    1014  1015  1016    1017    1018    1019    1020  
img
TM 5-3895-369-14
NOTE
End cap is under slight spring pressure.
Care should be taken when removing last
three screws.
(15) Remove screws (34 and 35), washers (36),
and lifting bracket (37).
(16) Remove end cap (15) from motor (3).
(17) Remove gasket (38), bearing race (39), and
valve plate (40) from motor end cap (15).
Discard gasket.
(18) If damaged, remove pin (41).
(19) Remove bearing plate (42) and spacer (43)
from motor (3).
(20) If damaged, remove three pins (44 and 45).
(21) Remove rear bearing (46) and spacer (47).
5-348