TM 5-3895-369-14
(7) Remove screw (13) and chain (14) from
Plug (15).
(8) Remove plug (15) from tee (12).
(9) Remove chain (14) and split ring (16) from
nipple (17).
(10) Remove tee (12) with two nipples (17
and 18) from additive pump (19).
(11) If damaged, place tee (12) in vise and
remove two nipples (17 and 18) from
tee (12).
(12) If damaged, remove plug (20) from additive
pump (19).
b. Cleaning/Inspection.
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in well-ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.
Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type I
drycleaning solvent is 100F (38C) and for type II is 140F (60C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.
If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately flush
eyes with water and get immediate medical attention.
Compressed air used for cleaning purposes must not exceed 30 psi (207 kPa). Use only with effective
chip guarding and personal protective equipment (goggles/shield, gloves, etc.).
(1) Clean all metal parts and strainer with drycleaning solvent. Dry all metal parts with clean lint-free cloth or
compressed air.
(2) Inspect all parts for crack, wear, damaged threads, or missing parts.
(3) Replace all damaged or missing parts.
4-503