TM. 5-3895-369-14
(2) Matchmark pump (4) and mount (5).
screws (8). Discard lockwashers.
Additive pump weighs 297 lb. (135 kg).
Attach suitable lifting device prior
to removal to prevent possible injury
to personnel.
(4) While mechanic operates suitable lifting
device, assistant guides additive pump (4)
from mount (5).
b. Installation.
Additive pump weighs 297 lb. (135 kg).
Attach suitable lifting device prior to
installation to prevent possible injury to
personnel.
(1) While mechanic operates suitable lifting
device, assistant positions additive pump (4)
on mount (5) and aligns matchmarks.
nuts (6). Tighten nuts 75 lb-ft (102 Nm).
(3) Position hose (2) on pipe (3) and tighten
fitting (1).
NOTE
Follow-on Maintenance:
Install pump speed sensor
Install hydrostatic pump cover
END OF TASK
4-497