ADDITIVE (MIXER) PUMP ASSEMBLY REPLACEMENT
ADDITIVE CHAIN REPLACEMENT.

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  588    589    590    591    592  593  594    595    596    597    598  
img
. . .
TM. 5-3895-369-14
(2) Matchmark pump (4) and mount (5).
(3) Remove four nuts (6), lockwashers (7), and
screws (8). Discard lockwashers.
Additive pump weighs 297 lb. (135 kg).
Attach suitable lifting device prior
to removal to prevent possible injury
to personnel.
(4) While mechanic operates suitable lifting
device, assistant guides additive pump (4)
from mount (5).
b. Installation.
Additive pump weighs 297 lb. (135 kg).
Attach suitable lifting device prior to
installation to prevent possible injury to
personnel.
(1) While mechanic operates suitable lifting
device, assistant positions additive pump (4)
on mount (5) and aligns matchmarks.
(2) Install four screws (8), lockwashers (7), and
nuts (6). Tighten nuts 75 lb-ft (102 Nm).
(3) Position hose (2) on pipe (3) and tighten
fitting (1).
NOTE
Follow-on Maintenance:
Install additive chain (para 4-152).
Install pump speed sensor
(para 4-150).
Install hydrostatic pump cover
(para 4-97).
END OF TASK
4-497