• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
HYDRAULIC CROSS REPLACEMENT/REPAIR - Continued
PUMP SPEED/GROUND SPEED TRAVEL SENSOR REPLACEMENT

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  574    575    576    577    578  579  580    581    582    583    584  
img
. . . .
TM 5-3895-369-14
e.
Installation.
(1) Install two spacers (16) on studs (17).
(2) Install two clamps (18) and cross (6) on two
studs (17).
(3) Install two lockwashers (15), and nuts (14)
on studs (17).
(4) Connect hose (12) on king nipple (13) and
tighten clamp (11) on cross (6).
(5) Connect hose (10) and tighten fitting (9).
(6) Connect hose (8) and tighten fitting (7).
(7) Connect hose (5) and tighten fitting (4) on
cross (6).
(8) Connect hose (1) on fitting (2) of flow
control valve (3).
(9) Remove container and dispose of hydraulic
fluid in accordance with local regulations.
NOTE
Follow-on maintenance:
Install forward floor plate
(para 4-132).
Lower aft floor deck (para 2-15).
Turn on hydraulic valve (para 2-18).
Check hydraulic fluid level and add
fluid as needed (para 3-11).
END OF TASK
4-483