4-88. AUXILIARY BATTERY REPLACEMENT.
This task covers:
b. Installation
a. Removal
INlTlAL SETUP
Equipment Condition
Tools
Condition Description
TM or Para
Tool kit, general mechanic's: automotive
Battery cables
Para 4-90
disconnected.
.
Remove or disconnect batteries and turn master battery switch off prior to performing maintenance
in immediate battery area or working on electrical system. Such disconnections prevent electrical
shock to personnel or equipment.
.
Battery acid (electrolyte) is extremely harmful. Always wear safety goggles and rubber gloves, and do
not smoke when performing maintenance on batteries. Injury will result if acid contacts skin or eyes.
Wear rubber apron to prevent clothing being damaged.
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a direct
.
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
a.
Removal.
(1) Loosen two nuts (1) and rotate two battery hold-downs (2) away from auxiliary battery (3).
(2) Remove auxiliary battery (3) from battery box (4).