ADDITIVE PUMP TURNS BUT WILL NOT PUMP ADDITIVE SOLUTION - Continued
ADDITIVE PUMP TURNS BUT WILL NOT PUMP ADDITIVE SOLUTION - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  213    214    215    216    217  218  219    220    221    222    223  
img
TM 5-3895-369-14
ADDITIVE PUMP TURNS BUT WILL NOT PUMP ADDITIVE SOLUTION (CONT).
KNOWN INFO
TEST OPTIONS
Camlock-OK.
Vottage test.
Control valve-OK.
REASON FOR QUESTION
If 12 to 14 Vdc is not present at
input side of pump speed
control, indicates faulty pump
speed control.
POSSIBLE PROBLEMS
Faulty pump speed control.
Faulty flow control power
switch.
Faulty hydraulic pressure
switch.
Faulty additive pump.
KNOWN INFO
TEST OPTIONS
Camlock-OK.
Voltage test.
Control valve-OK.
IPump speed control-OK
REASON FOR QUESTION
If flow control power switch
reads voltage greater than 0,
indicates faulty switch.
POSSIBLE PROBLEMS
Faulty flow control power
switch.
Faulty hydraulic pressure
switch.
Faulty additive pump.