ADDITIVE PUMP TURNS BUT WILL NOT PUMP ADDITIVE SOLUTION - Continued
ADDITIVE PUMP TURNS BUT WILL NOT PUMP ADDITIVE SOLUTION - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  212    213    214    215    216  217  218    219    220    221    222  
img
. . . .
TM 5-3895-369-14
SOLENOID VOLTAGE TEST
(1) Remove forward floor plate
(para 4-132).
(2) Power up STE/ICE-R to engine battery
(TM 9-4910-571-12&P, in TK mode).
(3) Start engine (para 2-9).
(4) Follow Additive System Operating
Procedures (pare 2-12[a]) steps 3-6.
(5) Perform voltage test # 89 at input side
(1) of flow control valve solenoid.
(a) If 12 to 14 Vdc is present at
input side of solenoid, perform
continuity test.
(b) lf 12 to 14 Vdc is not present at
input side of solenoid, go to
step # 4.
SOLENOID CONTINUITY TEST
(1) Remove forward floor plate
(para 4-132).
(2) Power up STE/ICE-R to engine battery
(TM 9-4910-571-12&P, in TK mode).
(3) Perform continuity test # 91 across
flow control valve solenoid wire
connector (1).
(a) If continuity test is 0, replace
flow control valve (para 4-138).
(b) If continuity is greater than 0,
indicates faulty pressure sensor.
4-121