UNUSUAL ENGINE NOISE - Continued
UNUSUAL ENGINE NOISE - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  198    199    200    201    202  203  204    205    206    207    208  
img
. . . .
TM 5-3895-369-14
AIR INLET PIPE INSPECTION
(1) Open left engine door (para 2-14).
(2) Check for air leaks in pipes between
turbocharger and manifold cover.
(a) lf there are leaks in air inlet
pipe, repair or replace them as
necessary (para 4-45).
(b) lf air inlet pipes are OK,
indicates faulty air access cover
or gasket.
MANIFOLD COVER
INSPECTION
(1) Disconnect negative battery cable
(para 4-90).
(2) Inspect manifold cover for obvious
damage that would cause a leak.
(a) If gasket is damaged, replace
(para 4-46).
(b) If gasket is not damaged,
indicates faulty turbocharger
gasket.
4-l07