Table 2-2. Operator Preventive Maintenance Checks and Services - Continued
Table 2-2. Operator Preventive Maintenance Checks and Services - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  38    39    40    41    42  43  44    45    46    47    48  
img
TM 5-3695-369-14
Table 2-3. Operator Preventive Maintenance Checks and Services - CONT.
Location
Not Fully Mission
Procedure
Item to
Interval
Item
Capable If:
Check/Service
No.
INTERIOR -
CONT.
Instrument panel - c. Tachometer:
During
5
Needle moves when throttle is
continued
actuated.
1100 rpm at idle.
2000 rpm at rated.
d. Voltmeter:
Normal operating range is between 24
volts and 28.5 volts.
e. Vacuum Indicator, Hydraulic
Oil Filter:
Check position of indicator needle. If it
enters the Red Danger Zone, the filter
element should be cleaned or replaced.
f. TGP, FPM, and GPM Digital Meters:
Activate toggle switches. Check meters
for digital ON display.
Check for proper operation.
Backup alarm,
During
6
horn, lights, etc.
EXTERIOR
Read and understand all of the safety
precautions and warnings before
performing any checks and services or
personal injury can result.
Additive system is plugged
Close valve at the supply tank and with
Additive System
7
After
spray bar ON, loosen feed hose fitting at the with additive material.
supply tank. Continue pumping until only
air comes out of the spray nozzles. Flush
additive system with an appropriate cleaner
before shutting down.
Tines are unserviceable.
Check for cracks, dents, distortion, and
Tines, Mixing
8
After
insecure mounting.
2-26