TM5-3895-369-14
5-46. ALTERNATOR ASSEMBLY REPAIR (CONT).
(2)
Measure resistance of excitation winding in
rotor at points C and D. Resistance value is
7.0Ohm
to
7.1Ohm.
(3)
Test stator for short circuit at points E and F
with 80 Vac. Indicator lamp must not
light up.
(4)
Measure resistance of stator windings
between phase lead-out wires (point E).
Resistance value 0.14 Ohm to 0.24 Ohm.
d . A s s e m b l y .
(1)
Install bearing (26) on rotor (16).
(2)
Install plate (25), bearing (24), and
collar (23).
5-288