TM 5-3895-369-14
(3)
Install bearings (9 and 8) on drive gear (10).
(4)
Install drive gear assembly (7) in drive
housing (2).
Adhesive causes immediate bonding on
contact with eyes, skin, or clothing and also
gives off harmful vapors. Wear protective
goggles and use in well-ventilated area. If
adhesive gets in eyes, try to keep eyes open;
flush eyes with water for 15 minutes and
get immediate medical attention.
NOTE
In order to secure plate while adhesive
sealant drys, four nuts from output flange
assembly must be installed.
(5)
Apply sealant compound to face of drive
housing (2) and install adaptor plate (6).
5-228