4-85. BACK-UP HORN ALARM SWITCH REPLACEMENT (CONT).
NOTE
Note position of back-up switch arm for
installation.
(2)
Remove two screws (5), lockwashers (6), and
back-up horn switch (4) from bracket (7).
Discard lockwashers.
b. Cleaning/lnspection.
(1)
Wipe parts clean with lint-free cloth.
(2)
Check wires for cracks or fraying.
(3)
Check metal parts for cracks, rust, holes, or
other damage.
(4) Replace damaged parts.
c.
Installation.
(1)
(2)
Install back-up horn switch (4) on bracket (7) with two screws (5) and lo&washers (6).
Install two wires (2 and 3) on switch (4) with
two screws (1).
NOTE
Follow-on Maintenance:
.
Install hydrostatic pump cover
(para 4-96).
.
Connect negative battery cable
(para 4-90).
END OF TASK