5-61. PILLOW
TM 5-3895-369-14
c.
Assembly.
Adhesive sealant causes immediate
bonding on contact with eyes, skin, or
clothing and also gives off harmful vapors.
Wear protective goggles and use in well-
ventilated area. If adhesive gets in eyes, try
to keep eyes open; flush eyes with water for
15 minutes and get immediate medical
attention.
(1)
Coat threads of elbow (19) and grease
fitting (18) with pipe thread sealing
compound and install in pillow block
housing (1).
(2)
Coat threads of four plugs (16, 15, 14, and
13) with pipe thread sealing compound and
install gasket (17) and plugs.
(3)
Lubricate two bearings (11) and pack housing (1) with grease.
(4)
Install two rings (12) on bearings (11).
(5)
Install one bearing (11) in housing (1) and other bearing (11) on shaft (6).
(6)
Install shaft (6) in housing (1), making sure rings (12) are seated in housing.