5-73. MASTER CYLINDER REPAIR (CONT).
a.
Disassembly.
End plug is under spring pressure. Care
should be taken during disassembly. Spring
can cause serious injury to personnel.
(1) Remove end plug (1) from housing (2).
(2) Remove check valve spring (3). check
valve (4), and check valve seat (5).
(3) Remove retainer (6), spring (7), and
preformed packing (8). Discard
preformed packing.
(4) Remove gasket (9). spanner retainer (10),
and seat (11) from retainer (6).