ADDITIVE INSTRUMENT PANEL REPAIR - Continued
ADDITIVE INSTRUMENT PANEL REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  603    604    605    606    607  608  609    610    611    612    613  
img
TM 5-3895-369-14
4-155. ADDITIVE INSTRUMENT PANEL REPAIR (CONT).
(26) Remove four nuts (51). lockwashers (52),
and screws (53). Discard lockwashers.
(27) Remove two box mounts (54) from box (3).
b. Inspection.
(1) Wipe parts clean with lint-free cloth.
(2) Check metal parts for damage.
(3) Check wires, terminals, and fuses for cracks,
burns, fraying, or other damage.
(4) Test wires for continuity.
(5) Replace damaged parts.
Assembly.
c.
(1) Install two box mounts (54) on box (3) with four screws (53), lockwashers (52), and nuts (51).
(2) Install terminal board (50) in box (3) with
two screws (49), lockwashers (48), and
nuts (47).