FIREWALL INSTRUMENT REPLACEMENT - Continued
FIREWALL INSTRUMENT REPLACEMENT - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  401    402    403    404    405  406  407    408    409    410    411  
img
TM 5-3895-369-14
4-78. FIREWALL INSTRUMENT REPLACEMENT (CONT).
(18) Remove fuse cover (43) and fuse (44) from
fuse port (45).
(19) Remove two leads (46) at rear of fuse
port (45).
(20) Remove jamnut (47) and fuse port (45) from
firewall (15).
(21) Remove three screws (48) and leads (49)
from switches (50).
(22) Remove two rubber boots (51),
jamnuts (52), and washers (53) from
switches (50).
(23) Remove switches (50) from firewall (l5).
b. Cleaning/Inspection.
(1) Check all gauges, leads, and switches for
proper connections.
(2) Check for damaged parts.
(3) Replace all damaged parts.
Installation.
c.
(1) Install switch (50) to firewall (15).
(2) Install washers (53), jamnuts (52), and two
rubber boots (51) to switches (50).
(3) Install three leads (49) with screws (48) to
switches (50).