EXCESSIVE VIBRATION - Continued
UNUSUAL ENGINE NOISE

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  192    193    194    195    196  197  198    199    200    201    202  
img
. . . .
TM 5-3895-369-14
FAN HUB INSPECTION
(1) Remove drive belt (para 4-68).
(2) Measure fan end play at position A.
(a) If measurement is greater than
0.006 inch (0.15 mm), replace fan
support.
(b) If fan hub is OK, indicates faulty
drive line components.
DRIVE LINE INSPECTION
(1) Start engine (para 2-9).
(2) Engage pump drive shaft and clutch
drive shaft (para 2-10).
(a) Check for excessive vibration
at drive shafts, replace/repair as
necessary (para 4-100, 4-101, and
4-102).
(b) If no obvious damage or
looseness, notify supervisor.